AWM5104VC Flow sensor, amplified, 0 - 20 slpm

reichelt elektronik

AWM5104VC Flow sensor, amplified, 0 - 20 slpm RSS 221.40 221.40 EUR944.51 PLN
  • Sklep zagraniczny
MPN:
AWM5104VC
Kod:
151368
Producent:
HONEYWELL
GTIN-13:
9900001513688
Waluta:
euro
Dodany do bazy:
Ostatnio widziany:
Zmiana ceny:
+2.27% (07.04.2025)
Poprzednia cena:
216.48 EUR

Inline flow measurement Micro-bridge air flowmeters for high throughput in the AWM5000 series are accommodated in flow enclosures that function like venturi nozzles. They measure air flows of up to 20 standard litres per minute (slpm) and cause a maximum pressure drop of 2.25 inches H2O. The micro-bridge chip is in direct contact with the air current, which significantly reduces the risk of measuring errors due to a restriction of the diaphragm or bypass channel.

Rugged, versatile enclosure The rugged plastic enclosure is constructed to withstand system pressures of up to 50 psi and the small sensor withstands shocks of up to 100 g without sacrificing performance. The built-in AMP-compatible connector ensures reliable connection in the most demanding applications.

Integrated signal conditioning Each AWM5000 sensor contains circuits for gain, linearisation, temperature compensation and gas calibration. Independently of the flow range (5, 10, 15, or 20 SLPM) or the calibration gas (nitrogen, carbon dioxide, nitrous oxide or argon), all models provide the possibility of linear output from 1 - 5 V DC. All calibrations are performed using active laser comparison

- Linear voltage output - Venturi design - Remote mounting possible - Active laser comparison for improved interchangeability - Various gas calibrations: - Ar (argon) - N2 (nitrogen) or - CO2 (carbon dioxide)

Technical product data: Signal conditioning: Amplified Flow/pressure range: 0 SLPM to 20.0 SLPM Output voltage at the calibration point: 5.0 V DC at 20 SLPM Connection type: 1/4 inch - 18 NPT Zero offset for temperature changes: 0.050 V DC typical, 0.20 V DC max. Output offset for changes in temperature: ±10% of measuring range Flow rate change: 5.0 SLPM/s Repeatability: ±0.50% of measuring range Zero offset: 0.95 V DC min., 1 V DC typical, 1.05 V DC max. Response time: 60 ms max. Supply voltage: 8.0 V DC min., 10.0 V DC typical, 15.0 V DC max. System pressure: 50 psi Power consumption: 100 mW max. Operating temperature: -20 - +70°C Media compatibility: dry gas only Shock: max. 100 g 6 ms half-sine pulse (3 impacts in 3 axis directions)