UVC-0002 UV-C disinfection station 120W with 4 tubes for 60 m² room area,
reichelt elektronik
RSS
412.41 EUR1759.38 PLN
- Sklep zagraniczny
- MPN:
- UVC-0002
- Kod:
- 292419
- Producent:
- GOOD CONNECTIONS
- GTIN-13:
- 4014619709984
- Waluta:
- euro
- Dodany do bazy:
- Ostatnio widziany:
- Zmiana ceny:
- -54% (18.02.2023)
- Poprzednia cena:
- 899.19 EUR
The UV-C disinfection station from Good Connections® ensures environmentally friendly UV-C disinfection without the use of chemicals and is used in rooms with an area of up to 60 m², whether in offices, schools, public institutions, conference centres, hotels or the catering trade. The UV-C disinfection lamp can be transported effortlessly from room to room using the 360° rotating castors.
safety shutdown on movement The UV-C disinfection lamp from Good Connections® is equipped with an infrared motion sensor. If movement is detected, the disinfection process is stopped immediately. After leaving the room, the disinfection process is continued.
Timer for setting the disinfection process Disinfection times between 15 minutes and 1440 minutes can be selected. A minimum duration of 30 minutes is recommended for a room area of 60 m². The switch-on delay is 15 seconds, allowing the operator to leave the room.
Two adjustable lamp arms each with two UV-C tubes The lamp arms automatically engage at the following angles: 30°, 45°, 75°, 90°, 145° and 165°. For safe storage, the lamp arms can be folded down after use and stored behind a protective cover.
Technical Specification:
- Carbon steel housing - UV tube output: 30 W each - Number of UV tubes: 4 pieces - UV wavelength: 253.7 nm - UV illuminance: = 428 uW / cm² - Area of application: For rooms up to 60 m² area - voltage: 230V / 110V ±10 %, frequency: 50/60 Hz ±10%. - Input power: 180 VA - Lamp arms individually switchable - Side compartments for safe storage of the lamps - Gradual adjustment of the angle of the UV lamps (30°/45°/75°/90°/145°/165°) - Timer for setting the lighting time between 15 minutes and 1440 minutes - Switch-on delay for UV-C lamps is 15 seconds
Weight: 24 kg
Notes: The product is not a medical device and therefore its use for this purpose is not allowed. UV-C radiation poses a hazard to the eyes and skin and can cause skin reddening, severe burns, conjunctivitis and corneal inflammation. It is imperative that you read the operating instructions and the safety instructions before use. The UV tubes should be replaced if the UV illuminance is reduced by more than 70% or after 2000 operating hours. Suitable UV tubes are available under the Good Connections® article number ET-2001 / EAN: 4014619708819
Elecena nie prowadzi sprzedaży elementów elektronicznych, ani w niej nie pośredniczy.
Produkt pochodzi z oferty sklepu reichelt elektronik